Diesel Generator Sets
C1.1 Generator Set
-
Maximum Rating8.8 ekW
-
Minimum Rating8.0 ekW
-
EmissionsR96/EUIIIa Equivalent
-
Voltage110 to 480 Volts
Generator Set Specifications
- Maximum Rating
- 8.8 ekW
- Minimum Rating
- 8.0 ekW
- Emissions
- R96/EUIIIa Equivalent
- Voltage
- 110 to 480 Volts
- Frequency
- 60 Hz
- Speed
- 1800 rpm
- Duty Cycle
- Standby, Prime
Engine Specifications
- Engine Model
- C1.1, In-line 4, 4-cycle diesel
- Bore
- 3 in
- Stroke
- 3.2 in
- Displacement
- 69 in³
- Compression Ratio
- 23.0:1
- Aspiration
- Naturally Aspirated
- Fuel System
- Indirect Injection
- Governor Type
- Mechanical
Generator Set Dimensions
- Length
- 55.1 in
- Width
- 24.4 in
- Height
- 39.2 in
-
Air Inlet System
- Air cleaner; light duty with disposable element
-
Control Panel
- GCCP 1.3
-
Cooling System
- Coolant drain line with valve
- Caterpillar extended life coolant
- Radiator and cooling fan with guards
- Fan drive, battery charging alternator drive
-
Exhaust System
- Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
-
Fuel System
- Base, formed steel with single wall integral 8-hour fuel tank
- Standard open set fuel tank/base supplied
-
Generators and Generator Attachments
- 12 Leads
- IP23 Protection
- Segregated low voltage (AC/DC) wiring panel
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- Voltage regulator (single phase sensing)
- Tower panel, IP22, bottom cable entry
-
Governing System
- Mechanical governing system
-
Lube System
- Lubricating oil
- Oil drain line with valve
-
Mounting System
- Includes lifting provisions and termination points for coolant
- Captive linear vibration isolators between base and engine-generator
-
Starting / Charging System
- 12 Volt battery with rack and cables
-
General
- Engine and alternator pre-paint, Caterpillar yellow
-
Alternator Options
- Coastal insulation protection
-
Certificates
- European upgrade to STD set for CE certificate
- Global certification for CIS
-
Circuit breakers
- Padlockable breaker device
- 4 Pole Circuit breaker
-
Control Panel
- Battery charger
- Volt free contacts for common alarm
- Volt free contacts for genset running
- Emergency stop with key
- GCCP 1.3
-
Cooling System
- Coolant heater
-
Enclosures
- Single point lift for enclosure
- Sound attenuated enclosure (GALV)
-
Fuel System
- Fuel transfer control
- Base feet
- 1000 hr extended service interval
- Skidbase for enclosures
- Skidbase for open sets
- DEFRA bunded fuel tank
- Low fuel level alarm
-
Mounting Options
- Industrial silencer removal
- Battery removal
- Silencer installation kit
-
Special Test and Inspection
- PGS Test report @ 1.0 power factor
-
General
- Radiator stone guard
- Packing case - canopied set
- Packing case - compact set