Diesel Generator Sets
C1.5 Generator Set
-
Maximum Rating13.2 ekW
-
Minimum Rating12.0 ekW
-
EmissionsR96/EUIIIa Equivalent
-
Voltage110 to 415 Volts
Generator Set Specifications
- Maximum Rating
- 13.2 ekW
- Minimum Rating
- 12.0 ekW
- Emissions
- R96/EUIIIa Equivalent
- Voltage
- 110 to 415 Volts
- Frequency
- 60 Hz
- Speed
- 1800 rpm
- Duty Cycle
- Standby, Prime
Engine Specifications
- Engine Model
- Cat® C1.5
- Bore
- 3.3 in
- Stroke
- 3.5 in
- Displacement
- 91.3 in³
- Compression Ratio
- 22.5:1
- Aspiration
- Naturally Aspirated
- Fuel System
- Indirect Injection
- Governor Type
- Mechanical
Generator Set Dimensions
- Length
- 55.1 in
- Width
- 24.4 in
- Height
- 41.5 in
-
Air Inlet System
- Air cleaner; light duty with disposable element
-
Control Panel
- GCCP 1.3
-
Cooling System
- Radiator and cooling fan with guards
- Coolant drain line with valve
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
-
Exhaust System
- Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
-
Fuel System
- Base, formed steel with single wall integral 8-hour fuel tank
- Standard open set fuel tank/base supplied
-
Generators and Generator Attachments
- Voltage regulator (single phase sensing)
- IP23 Protection
- Segregated low voltage (AC/DC) wiring panel
- Tower panel, IP22, bottom cable entry
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- 12 Leads
-
Governing System
- Mechanical governing system
-
Lube System
- Oil drain line with valve
- Lubricating oil
-
Mounting System
- Captive linear vibration isolators between base and engine-generator
- includes lifting provisions and termination points for coolant
-
Starting / Charging System
- 12 Volt battery with rack and cables
-
General
- Engine and alternator pre-paint, Caterpillar yellow
-
Alternator Options
- Coastal insulation protection
-
Certificates
- Global certification for CIS
- European upgrade to STD set for CE certificate
-
Circuit breakers
- Padlockable breaker device
- 4 Pole Circuit breaker
-
Control Panel Options
- Emergency stop with key
- Volt free contacts for genset running
- Battery charger
- Volt free contacts for common alarm
- GCCP 1.3
-
Cooling System
- Coolant heater
-
Enclosures
- Sound attenuated enclosure (GALV)
- Single point lift for enclosure
-
Fuel System
- Low fuel level alarm
- DEFRA bunded fuel tank
- 1000 Hr extended service interval
- Fuel transfer control
- Skidbase for open sets
- Base feet
- Skidbase for enclosures
-
Mounting Options
- Silencer installation kit
- Industrial silencer removal
- Battery removal
-
Special Test and Inspection
- PGS Test report @ 1.0 power factor
-
General
- Packing case - canopied set
- Packing Case - compact set
- Radiator stone guard