Piscataway Campus
732-885-5555
Bensalem Campus
877-726-7663

Diesel Generator Sets

DE33 GC Generator Set (60 Hz)

  • Maximum Rating
    30.0 ekW
  • Minimum Rating
    30.0 ekW
  • Emissions
    Non Regulated
  • Voltage
    220 to 480 Volts
Generator Set Specifications
Maximum Rating
30.0 ekW
Minimum Rating
30.0 ekW
Emissions
Non Regulated
Voltage
220 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby
Engine Specifications
Engine Model
Cat® C3.3, In-line 3, 4-cycle diesel
Bore
4.1 in
Stroke
5 in
Displacement
201.4 in³
Compression Ratio
19.25:1
Aspiration
Naturally Aspirated
Fuel System
Inline
Governor Type
Mechanical
Generator Set Dimensions
Length
76.6 in
Width
34.3 in
Height
48.7 in
Dry Weight
2114 lb
  • Engine
    • C3.3, Inline 3 cylinder, 4 stroke diesel
  • Genset Control
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Enclosure
    • Cat GC enclosure
  • Air, Cooling & Exhaust
    • Enclosure silencer
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • Certification
    • Certificate of Conformance
    • Australia, CIS, Gulf Certification
  • Alternator Requirements
    • Space heater
  • Auxiliary Supply Voltage
    • 120V
  • Fuel Storage
    • Dual wall 8 hour fuel tank
    • Low fuel level shutdown
    • Single wall tank with containment
    • Low fuel level alarm
    • High fuel level alarm
  • Genset Control
    • Battery charger
    • Volt free contacts for genset running
    • Volt free contacts for common alarm
    • Earth fault
    • Panel mounted audible alarm
    • USB to RS485 Communications device
    • Emergency stop with key
    • Earth leakage
    • Low coolant level shutdown
    • Coolant heater
    • Standby Pack (Smart Jacket water heater, Battery charger)
    • Battery
  • Circuit breaker
    • 3 Pole Circuit breaker 80A
    • 3 Pole Circuit breaker 63A
    • 3 Pole Circuit breaker 100A
    • 3 Pole Circuit breaker 125A
    • 3 Pole Circuit breaker 160A
    • 3 Pole Circuit breaker 200A
    • 4 Pole Circuit breaker 80A
    • 4 Pole Circuit breaker 63A
    • 4 Pole Circuit breaker 100A
    • 4 Pole Circuit breaker 125A
    • 4 Pole Circuit breaker 160A
    • 4 Pole Circuit breaker 200A
    • Circuit breaker padlock
    • Neutral earth link
    • Overload via alarm switch on breaker
  • Testing & Packaging
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor