Diesel Generator Sets

D50 GC Generator Set

  • Maximum Rating
    50 ekW
  • Minimum Rating
    50 ekW
  • Emissions
    U.S. EPA Cert., Tier 3, SCAQMD Compliant
  • Voltage
    208 to 600 Volts
Generator Set Specifications
Maximum Rating
50 ekW
Minimum Rating
50 ekW
Emissions
U.S. EPA Cert., Tier 3, SCAQMD Compliant
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby
Engine Specifications
Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1 in
Stroke
5 in
Displacement
269 in
Compression Ratio
18.2:1
Aspiration
Turbocharged
Fuel System
Common Rail
Governor Type
Mechanical, ADEM™A4
Generator Set Dimensions
Length
77.2 in
Width
43.3 in
Height
48 in
Dry Weight
2055 lb
  • Certificates
    • IBC seismic and wind Certifications
  • Air Inlet System
    • Air cleaner
    • Cartridge type air filter
  • Circuit breakers
    • Second circuit breaker box
    • Power terminal strip
    • Breakers (100% UL rated)
    • 3-Pole 100% rated
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Control Panel
    • GCCP 1.2 Control panel
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
  • Cooling System
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
    • Radiator and cooling fan with guards
    • Coolant drain line with valve
    • Radiator stone guard
  • Control Panels
    • NFPA110 bundle includes:
    • WCA1 Low coolant temperature alarm
    • FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
    • WSS1 Low coolant level shut down
    • PBC10NU NFPA battery charger
    • Oil temperature gauge and sender
    • PAA1 Panel mounted audible alarm
    • A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
    • Audible alarm
    • Remote E-stop button
    • Ground fault relay
    • Discrete I/O module
    • Remote annunciator module
    • Volt free contacts genset run and common alarm
    • Fuel level reading
    • Protective devices:
    • Low coolant temperature alarm
    • Low coolant level shutdown
    • Overload shutdown via breaker
  • Generator
    • 12 Leads
  • Governing System
    • Mechanical and electrical governing system - model dependent
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • Starting/Charging System
    • Batteries
    • 24V battery with rack and cables
  • Certificates
    • IBC seismic and wind Certifications
  • Air Inlet System
    • Cartridge type air filter
  • Alternator System
    • R Frame auxilliary winding
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Circuit breakers
    • Breakers (100% UL rated)
    • Power terminal strip
    • 3-Pole 100% rated
    • Second circuit breaker box
  • Control Panels
    • Volt free contacts genset run and common alarm
    • Oil temperature gauge and sender
    • Remote E-stop button
    • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
    • Audible alarm
    • Remote annunciator module
    • Discrete I/O module
    • NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
    • Ground fault relay
  • Cooling System
    • Radiator transition flange
  • Enclosures
    • External emergency stop
    • Sound attenuated enclosure, Level 2
    • Panel viewing window
  • Exhaust System
    • 10, 25 and 35 dBA silencer systems
    • Overhead silencer mounting kit
  • Fuel System
    • 5 Gallon spill containment
    • 209 and 394 gallon sub-base fuel tanks
    • Tank riser
    • Emergency vent pipe
    • 5 Gallon fill containment
  • Heating Elements
    • Coolant heater
    • Wiring for canopy space heater
    • Battery heater
    • Lube oil sump heater
    • Anti-condensation heater
    • Wiring for canopy space heater
    • Jacket water heater
  • Generators
    • Permanent magnet excitation (PMG) generator
    • Permanent magnet excitation (PMG) generator
  • Mounting System
    • Seismic vibration isolators
  • Tests
    • 4 Hour factory test
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
    • Generator test report