Piscataway Campus
732-885-5555
Bensalem Campus
877-726-7663

Marine Generator Sets

Cat C2.2 Marine Generator Set

  • Minimum Rating
    16 ekW (16kVA)
  • Maximum Rating
    25 ekW (25 kVA)
  • Maximum Rating
    27 ekW (27 kVA)
  • Frequency
    50 Hz or 60 Hz
Generator Set Specifications
Minimum Rating
16 ekW (16kVA)
Maximum Rating
25 ekW (25 kVA)
Maximum Rating
27 ekW (27 kVA)
Frequency
50 Hz or 60 Hz
Frequency
50 Hz or 60 Hz
Speed
1500 rpm (50Hz) or 1800 rpm (60 Hz
Speed
1500 rpm (50Hz) or 1800 rpm (60 Hz
Emissions
EPA Tier 3, IMO NST, EU IW
Minimum Rating
15 ekW (15 kVA)
Engine Specifications
Engine Model
C2.2, In-line 4, 4-Stroke-Cycle Diesel
Engine Model
C2.2, In-line 4, 4-Stroke-Cycle Diesel
Displacement
135 in³
Aspiration
Naturally Aspirated
Aspiration
Naturally Aspirated / Turbocharged
Bore
3.31 in
Governor Type
Electrical Ischronous
Stroke
3.94 in
Bore
3.31 in
Displacement
135.0 in3
Stroke
3.5 in
Governor Type
Electrical Ischronous
Fuel System
Fuel filter — RH or LH service, fuel priming, fuel transfer pump, flexible fuel lines
Rated Engine Speed
1500 / 1800 rpm
Emissions
U.S. EPA Tier 3
Configuration
Inline 4, 4-Stroke Cycle diesel
Refill Capacity
Lube Oil System w/oil filter change: 10.6 L (2.8 gal)
Oil Change Interval
500 hrs
Rotation from Flywheel End
Counterclockwise
Cooling
Hex or Single Circuit Keel
Generator Set Configurations
Emissions
EPA Tier 3, IMO NST, EU IW
Generator Specifications
Excitation
AREP
Pitch
2/3 pitch
Number of Poles
4
Number of Leads
4
Insulation
Class H
Voltage Regulation
±0.5%
Frame Size
2.2
IP Rating
23
Wave Form Deviation
<2%
Voltage Regulator
Steady State
Dimensions & Weights
Length
45 in
Length
46 in
Width
20.5 in
Width
24 in
Height
32 in
Height
31 in
Minimum Approximate Weight
857 lb
Maximum Approximate Weight
1027 lb
Generator Set Dimensions
Length
47.9 in / 1,219 mm (open) 50.7 in / 1,290 mm (enclosed)
Width
22.3 in / 567 mm (open) 24.7 in / 628 mm (enclosed)
Height
32.8 in / 835 mm (open) 31.0 in / 775 mm (enclosed)
Engine Dry Weight
857-1,027 lb / 386-466 kg
  • Standard Equipment
    • Single element air cleaner
    • Water-cooled exhaust manifold
    • Single or Three phase brushless generator
    • 12 or 24 volt electric starting motor
    • 12 volt 55 amp alternator
    • Single sided service points
    • Anti-vibration mounts.
    • Electronic automatic safety shutdowns
  • Optional Attachments
    • Sound attenuated enclosure (Factory Fit or Upgrade Kit)
    • Keel cooling kit
    • Basic, Deluxe and remote panel options
    • AC circuit breakers
    • Flexible fuel lines
    • Primary fuel filter/water separator
    • Siphon break
    • Exhaust system components
    • Insulated electrical system