Marine Generator Sets
Cat C32 ACERT Generator Set (EPA Tier 3)
-
Minimum Rating730 ekW (913 kVA)
-
Minimum Rating730 ekW (913 kVA)
-
Maximum Rating940 ekW (1175 kVA)
-
Maximum Rating940 ekW (1175 kVA)
Generator Set Specifications
- Minimum Rating
- 730 ekW (913 kVA)
- Minimum Rating
- 730 ekW (913 kVA)
- Maximum Rating
- 940 ekW (1175 kVA)
- Maximum Rating
- 940 ekW (1175 kVA)
- Frequency
- 60hz
- Frequency
- 60hz
- Speed
- 1800 rpm
- Speed
- 1800 rpm
- Emissions
- EPA Tier III
Engine Specifications
- Engine Model
- Vee-12, 4-stroke-Cycle-Diesel
- Aspiration
- Turbocharged and aftercooled
- Aspiration
- Turbocharged and aftercooled
- Bore
- 5.7 in
- Bore
- 5.7 in
- Stroke
- 6.38 in
- Stroke
- 6.38 in
- Displacement
- 1959.0 in3
- Displacement
- 1959 in³
- Governor Type
- Electronic
- Governor Type
- Electronic
- Fuel System
- MEUI
- Engine Model
- Vee-12, 4-stroke-Cycle-Diesel
Generator Set Configurations
- Emissions
- EPA Tier III
Generator Set Dimensions
- Width
- 60.2 in
- Width
- 60.2 in
- Height
- 65.6 in
- Height
- 65.6 in
- Weight
- 15721.0 lb
- Weight
- 15721 lb
- Length
- 162.8 in/4271 mm (minimum), 175.3 in/4452 mm (maximum)
Generator Specifications
- Excitation
- Permanent magnet
- Number of Poles
- 4
- Number of Bearings
- 2 roller bearings
- Number of Leads
- 6
- Insulation
- Class H
- IP Rating
- 23
- Voltage Regulator
- CDVR
-
AIR INLET SYSTEM
- Separate circuit after-cooled (SCAC)
- Turbocharger, jacket water cooled
- Turbocharger inlet, 152 mm (6 in) OD straight connection
-
CONTROL SYSTEM
- If an EMCP panel or MGCP option is not chosen as optional equipment, then start/stop controls must be provided by the customer
- Electronic diagnostics and fault logging
- Engine Protection Mode for extended ambient conditions
- Electronic fuel/air ratio control
-
COOLING SYSTEM
- Separate Circuit After-Cooling (SCAC) for Heat Exchanged (HEX) & Keel cooled engines
- Jacket Water (JW) and SCAC Heat Exchangers Shell & Tube for HEX cooled engines
- SCAC pump, gear driven
- Jacket water pump, gear driven
- Sea water pump, bronze impeller, gear driven, for HEX cooled engines only
- Jacket water HEX with Sea water pump Connections: 76.2 mm (3in) ID Standard
- 4 Bolt ANSI Flange Connection
- Jacket water HEX without Sea water pump Connection: 2.5" hose barb connection (inlet), 76.2 mm (3in) ID Standard 4 Bolt ANSI Flange (outlet)
- Keel Connections: 76.2 mm (3in) ID Standard 4 Bolt ANSI Flange Connection
- SCAC and JW shunt tanks for maintaining proper Pump inlet pressures
-
EXHAUST SYSTEM
- Water-cooled exhaust manifold & turbocharger
- 4 Bolt 130 mm (5.12 in) diameter flanged outlet
-
FLYWHEELS & FLYWHEEL HOUSINGS
- Flywheel Housing, SAE No. 0
- Flywheel, 18 inch, 136 teeth
- SAE standard rotation
-
FUEL SYSTEM
- Duplex Fuel Filters, Spin-on, RH service
- Fuel connections size: Supply JIC 37 Deg -10 (7/8-14), Return JIC 37 Deg -8 (3/4-16)
- Plate-type fuel cooler installed behind Aftercooler Shunt Tank
- Fuel transfer pump, gear driven
- Manual fuel priming pump
-
GENERATORS AND GENERATOR ATTACHMENTS
- SR5 form wound
- 2 roller bearings
- Permanent magnet excitation
- 4 pole, 6 leads, Series Star connected
- Caterpillar's Digital Voltage Regulator (CDVR)
- Marine Class H insulation, Class F temperature rise
- Surface mounted platinum (PT100) 3-wire RTDs, 2 per phase on stator and one each on support bearings
- Anti-condensation space heaters (2 elements - 240 VAC, 1000 Watts
- IP23 Protection suitable for use with Fixed Water Based Local Application Fire Fighting Systems (FWBLAFFS)
- System IV insulation for harsh environment protection
-
LUBE SYSTEM
- Simplex oil filters, RH service
- Deep sump oil pan
- RH service oil filler locations
- RH service dipstick
- Oil pump, gear driven
-
MOUNTING SYSTEM
- Formed C-channel rails, 300mm (11.81in) height
- Six shipped loose combined helical spring/rubber
- isolators for installation below package base
-
GENERAL
- Front Damper guard
- Common electrical bondng point on HEX and KEEL cooled engines
-
ALARM AND PROTECTION
- Remote panels
- MCS Controller
- Power analyzer module
- Oil level, exhaust temperature, air starting pressure, heat exchanger pressure sensors
-
EXHAUST SYSTEM
- Dry Elbows
- Flexible Fitting
- Flange
- Muffler
- Muffler Spark Arresting
- Rain Cap
-
AIR INLET SYSTEM
- Air Inlet Cleaner
- Closed Crankcase Ventilation
- Air inlet adapter
-
CHARGING SYSTEM
- Battery Chargers, Charging Alternators
-
CONTROL SYSTEM
- Load Sharing Attachment
-
FUEL SYSTEM
- Water Separator
-
LUBE SYSTEM
- Duplex Oil Filters, Sump Pump
-
PROTECTION SYSTEM
- Fuel and Oil Shielding
-
STARTING SYSTEM
- Electric Starting Motors - Single 24 Volt
- Air Starting Motor
- Dual Starting Motors (Electric and Air)
- Air Start Accessories
- Starting Aids - JW Heaters
- Battery Sets - 24 Volt - Dry