Piscataway Campus
732-885-5555
Bensalem Campus
877-726-7663

Marine Generator Sets

Cat C32 ACERT Generator Set (EPA Tier 3)

  • Minimum Rating
    730 ekW (913 kVA)
  • Minimum Rating
    730 ekW (913 kVA)
  • Maximum Rating
    940 ekW (1175 kVA)
  • Maximum Rating
    940 ekW (1175 kVA)
Generator Set Specifications
Minimum Rating
730 ekW (913 kVA)
Minimum Rating
730 ekW (913 kVA)
Maximum Rating
940 ekW (1175 kVA)
Maximum Rating
940 ekW (1175 kVA)
Frequency
60hz
Frequency
60hz
Speed
1800 rpm
Speed
1800 rpm
Emissions
EPA Tier III
Engine Specifications
Engine Model
Vee-12, 4-stroke-Cycle-Diesel
Aspiration
Turbocharged and aftercooled
Aspiration
Turbocharged and aftercooled
Bore
5.7 in
Bore
5.7 in
Stroke
6.38 in
Stroke
6.38 in
Displacement
1959.0 in3
Displacement
1959 in³
Governor Type
Electronic
Governor Type
Electronic
Fuel System
MEUI
Engine Model
Vee-12, 4-stroke-Cycle-Diesel
Generator Set Configurations
Emissions
EPA Tier III
Generator Set Dimensions
Width
60.2 in
Width
60.2 in
Height
65.6 in
Height
65.6 in
Weight
15721.0 lb
Weight
15721 lb
Length
162.8 in/4271 mm (minimum), 175.3 in/4452 mm (maximum)
Generator Specifications
Excitation
Permanent magnet
Number of Poles
4
Number of Bearings
2 roller bearings
Number of Leads
6
Insulation
Class H
IP Rating
23
Voltage Regulator
CDVR
  • AIR INLET SYSTEM
    • Separate circuit after-cooled (SCAC)
    • Turbocharger, jacket water cooled
    • Turbocharger inlet, 152 mm (6 in) OD straight connection
  • CONTROL SYSTEM
    • If an EMCP panel or MGCP option is not chosen as optional equipment, then start/stop controls must be provided by the customer
    • Electronic diagnostics and fault logging
    • Engine Protection Mode for extended ambient conditions
    • Electronic fuel/air ratio control
  • COOLING SYSTEM
    • Separate Circuit After-Cooling (SCAC) for Heat Exchanged (HEX) & Keel cooled engines
    • Jacket Water (JW) and SCAC Heat Exchangers Shell & Tube for HEX cooled engines
    • SCAC pump, gear driven
    • Jacket water pump, gear driven
    • Sea water pump, bronze impeller, gear driven, for HEX cooled engines only
    • Jacket water HEX with Sea water pump Connections: 76.2 mm (3in) ID Standard
    • 4 Bolt ANSI Flange Connection
    • Jacket water HEX without Sea water pump Connection: 2.5" hose barb connection (inlet), 76.2 mm (3in) ID Standard 4 Bolt ANSI Flange (outlet)
    • Keel Connections: 76.2 mm (3in) ID Standard 4 Bolt ANSI Flange Connection
    • SCAC and JW shunt tanks for maintaining proper Pump inlet pressures
  • EXHAUST SYSTEM
    • Water-cooled exhaust manifold & turbocharger
    • 4 Bolt 130 mm (5.12 in) diameter flanged outlet
  • FLYWHEELS & FLYWHEEL HOUSINGS
    • Flywheel Housing, SAE No. 0
    • Flywheel, 18 inch, 136 teeth
    • SAE standard rotation
  • FUEL SYSTEM
    • Duplex Fuel Filters, Spin-on, RH service
    • Fuel connections size: Supply JIC 37 Deg -10 (7/8-14), Return JIC 37 Deg -8 (3/4-16)
    • Plate-type fuel cooler installed behind Aftercooler Shunt Tank
    • Fuel transfer pump, gear driven
    • Manual fuel priming pump
  • GENERATORS AND GENERATOR ATTACHMENTS
    • SR5 form wound
    • 2 roller bearings
    • Permanent magnet excitation
    • 4 pole, 6 leads, Series Star connected
    • Caterpillar's Digital Voltage Regulator (CDVR)
    • Marine Class H insulation, Class F temperature rise
    • Surface mounted platinum (PT100) 3-wire RTDs, 2 per phase on stator and one each on support bearings
    • Anti-condensation space heaters (2 elements - 240 VAC, 1000 Watts
    • IP23 Protection suitable for use with Fixed Water Based Local Application Fire Fighting Systems (FWBLAFFS)
    • System IV insulation for harsh environment protection
  • LUBE SYSTEM
    • Simplex oil filters, RH service
    • Deep sump oil pan
    • RH service oil filler locations
    • RH service dipstick
    • Oil pump, gear driven
  • MOUNTING SYSTEM
    • Formed C-channel rails, 300mm (11.81in) height
    • Six shipped loose combined helical spring/rubber
    • isolators for installation below package base
  • GENERAL
    • Front Damper guard
    • Common electrical bondng point on HEX and KEEL cooled engines
  • ALARM AND PROTECTION
    • Remote panels
    • MCS Controller
    • Power analyzer module
    • Oil level, exhaust temperature, air starting pressure, heat exchanger pressure sensors
  • EXHAUST SYSTEM
    • Dry Elbows
    • Flexible Fitting
    • Flange
    • Muffler
    • Muffler Spark Arresting
    • Rain Cap
  • AIR INLET SYSTEM
    • Air Inlet Cleaner
    • Closed Crankcase Ventilation
    • Air inlet adapter
  • CHARGING SYSTEM
    • Battery Chargers, Charging Alternators
  • CONTROL SYSTEM
    • Load Sharing Attachment
  • FUEL SYSTEM
    • Water Separator
  • LUBE SYSTEM
    • Duplex Oil Filters, Sump Pump
  • PROTECTION SYSTEM
    • Fuel and Oil Shielding
  • STARTING SYSTEM
    • Electric Starting Motors - Single 24 Volt
    • Air Starting Motor
    • Dual Starting Motors (Electric and Air)
    • Air Start Accessories
    • Starting Aids - JW Heaters
    • Battery Sets - 24 Volt - Dry