Piscataway Campus
732-885-5555
Bensalem Campus
877-726-7663

Diesel Generator Sets

D500 GC (60 Hz) Generator Set

  • Maximum Rating
    500 ekW
  • Minimum Rating
    500 ekW
  • Emissions
    EPA Stationary Emergency
  • Voltage
    480 to 600 Volts
Generator Set Specifications
Maximum Rating
500 ekW
Minimum Rating
500 ekW
Emissions
EPA Stationary Emergency
Voltage
480 to 600 Volts
Frequency
60 Hz
Speed
1800 RPM
Duty Cycle
Standby
Engine Specifications
Engine Model
Cat® C15 In-line 6, 4-cycle diesel
Bore
5.4 in
Stroke
6.8 in
Displacement
928 in³
Compression Ratio
16.1:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
MEUI
Governor Type
ADEM™A4
Generator Set Dimensions
Length
189.6 in
Width
64.2 in
Height
2034 in
Height
101.7 in
Dry Weight
8280.6 lb
Dry Weight
10346.3 lb
  • Air Inlet System
    • Air cleaner - Non canister, disposable
    • Turbocharger
    • Aftercooler core
  • Control Panel
    • GCCP 1.2
  • Cooling System
    • Blower fan and fan drive with guards
    • Jacket water pump, gear driven, centrifugal
    • Radiator sight gauge
    • Coolant drain valve
    • Thermostats and housing
    • Radiator, package mounted
  • Exhaust System
    • Exhaust manifold - dry
  • Fuel System
    • Engine fuel transfer pump
    • Primary fuel filter w/integral water separator and secondary filter, spin on
    • Integral tank base, 24 hours, UL142
    • Fuel cooler
    • Fuel priming pump
  • Generator Set
    • All protective devices and control functions simulated and checked
    • Factory tested to design specifications at full load conditions
    • Complete system designed & built at ISO 9001:2000 certified facilities
  • Generators and Generator Attachments
    • Easy access to AVR and terminals
    • Standard winding protection for non-harsh environments with relative humidity ? 95%
    • IP23 Protection
    • 6 Leads
    • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
    • Terminal box, IP22 RHS facing, bottom cable entry
    • Voltage regulator (single phase sensing)
    • Insulation system, Class H
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Lube System
    • Shallow oil pan
    • Oil filter, spin on
    • Oil drain with valve
    • Lubricating oil, CK-4 (10W-30)
    • Oil cooler
    • Oil filler and dipstick
    • Fumes disposal to front of radiator
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Protection
    • Safety shutoff - High water temperature
    • Safety shutoff - Overspeed
    • Safety shutoff - Low oil pressure
  • Starting/Charging System
    • 24V, 45 Amp Charging alternator
    • 24-volt electric starting motor
  • General
    • Lifting eyes
    • Vibration damper
    • Parts book
  • Air Inlet System
    • Air cleaner (Non canister disposable)
  • Bases, Mounting & Fuel Tanks
    • Audio & visual fuel alarm (@90% fuel level)
    • Wide Base - Skid
    • 5 Gallon Spill Containment
    • Fuel tank pill pipe & lockable cap
    • Overfill prevention valve
    • Integral tank base, 24 hours, UL142
  • Exhaust
    • Industrial, residential, critical mufflers
  • Circuit breaker
    • Auxiliary contacts
    • 600A LSI
    • 600A LS/I
    • 1200A LSI
    • 1200A LS/I
    • 400A LSI
    • 800A LSI
    • 800A LS/I
    • 400A LS/I
  • Control System
    • Twist release, Red button emergency stop
    • Ground fault relay
    • 20A GFCI (Ground Fault Circuit Interrupter)
    • Volt free contacts
    • Product link remote monitoring hardware
    • Audible alarm Gp
    • 16 -light NFPA 99/110 Annunciator
    • 100A Load center
  • Enclosures
    • E-Stop
    • AC & DC Source lights
    • Sound attenuated Level 2 enclosure (White)
  • Exhaust System
    • Manifold and turbocharger guards
    • 8" Muffler - 25 dBA attenuation
    • Flexible exhaust connection
  • Generator
    • Anti-condensation heater
    • Oversize and premium generators
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
    • Permanent magnet excitation (PMG) generator
    • Space heater
  • Starting System
    • Jacket water heater
    • Battery charger (UL Certified)
    • Oversize battery set, 1400 CCA, 200 amp/hr
    • Standard battery set: 1000 CCA, 90 amp/hr.
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • General
    • CSA Certification
    • Extended Service Coverage
    • Generator test report
    • UL2200 Certification
    • CSA Certification
    • UL 2200 package
  • Lube System
    • Manual sump pump
  • Mounting System
    • Narrow skid base - replaces standard fuel tank base