Diesel Generator Sets
DE165E0 (50 Hz) Generator Set
-
Minimum Rating165 kVA
-
Maximum Rating165 kVA
-
EmissionsNon Regulated
-
Voltage220 to 415 Volts
Generator Set Specifications
- Minimum Rating
- 165 kVA
- Maximum Rating
- 165 kVA
- Emissions
- Non Regulated
- Voltage
- 220 to 415 Volts
- Frequency
- 50 Hz
- Speed
- 1500 rpm
- Duty Cycle
- Standby, Prime
Engine Specifications
- Engine Model
- Cat® C7.1
- Bore
- 4.1 in
- Stroke
- 5.3 in
- Displacement
- 427.8 in³
- Compression Ratio
- 16.0:1
- Aspiration
- Turbocharged, Air to Air Aftercooled
- Fuel System
- Inline
- Governor Type
- Mechanical
Generator Set Dimensions
- Length
- 98.4 in
- Width
- 44.1 in
- Height
- 60.2 in
- Dry Weight
- 3549 lb
-
Control panel
- GCCP Control panel
-
Alternator and Alternator attachments
- 12 Leads
- IP23 Protection
- Voltage regulator (single phase sensing)
- Tower panel, IP22, bottom cable entry
- Segregated low voltage (AC/DC) wiring panel
- Circuit breaker, IEC, 3 Pole, mounted in tower panel
-
Governing system
- Mechanical or electrical governing system
-
Cooling system
- Radiator and cooling fan with guards
- Coolant drain line with valve
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
-
Air inlet system
- Air cleaner; light duty with disposable element
-
Exhaust system
- Stub pipe, gaskets, raincap & SAE exhaust flange
- Industrial silencer
-
Fuel system
- Standard open set fuel tank/base
-
Lube system
- Lubricating oil
- Oil drain line with valve
-
Mounting system
- Captive linear vibration isolators
- Lifting provision and drag points
- Termination points for coolant and lube oil drain lines
-
Starting/charging system
- 12V Battery with rack & cables
-
General
- Engine and alternator pre-paint, Caterpillar yellow
-
Control panel
- GCCP Control panel
- Earth fault and earth leakage
- Emergency E-Stop with security key
- 4 Pole Circuit breaker
- Voltage and speed adjust potentiometer
-
Alternator and Alternator Attachments
- LC Frame alternator
- LC/M Frame alternator
- Space heater
- Permanent magnet excitation (PMG)
- Automatic voltage regulator
- Quadrature droop kit
-
Enclosures
- Level 1 and Level 2 sound attenuated enclosures
- Single point lifting frame
- Rental pack
- SBOX - CEE form sockets
-
Alarms and Shutdowns
- Common alarm
- Overload shutdown
- Low coolant level shutdown
- Low coolant temperature alarm
- Low fuel level alarm and shutdown
- High fuel level alarm
-
Engine
- Electronic governor
- Jacket water heater
- Battery charger
-
Fuel system
- Bunded base tank sized for a minimum of 12 hours running with 110% spill protection
-
Exhaust system
- Residential silencer 25 dBA
-
Certification
- Certificate of Conformance
- EAC Certification
-
Extended service coverage
- 3, 4, 5 and 10 Years