Piscataway Campus
732-885-5555
Bensalem Campus
877-726-7663

Diesel Generator Sets

3412C | 900 kVA 50Hz Generator Set

  • Maximum Rating
    680 kVA
  • Minimum Rating
    680 kVA
  • Emissions
    Low Fuel Consumption
  • Voltage
    380 to 415 Volts
Generator Set Specifications
Maximum Rating
680 kVA
Minimum Rating
680 kVA
Emissions
Low Fuel Consumption
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Prime
Engine Specifications
Engine Model
3412C TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
5.4 in
Stroke
6 in
Displacement
1648.86 in³
Compression Ratio
13:01
Aspiration
Turbocharged, Air to Air Aftercooled
Fuel System
Pump and Lines
Governor Type
ADEM™ A5
Generator Set Dimensions
Length
162.4 in
Width
75 in
Width
78.3 in
Height
75 in
Dry Weight
12039 lb
Dry Weight
13030 lb
  • Air Inlet System
    • Air cleaner, single element canister type with service indicator
  • Control Panel
    • GCCP Control panel
    • Emergency stop pushbutton
    • Overspeed
    • Text alarm/event descriptions
    • Low coolant temperature
    • Frequency (Hz)
    • Overcurrent (50 / 51)
    • 4 programmable relay outputs (Form A)
    • Volts (L-L & L-N)
    • Programmable protective relaying functions:
    • Warning/shutdownn with common LED indication of shutdowns for:
    • 24 Volt DC operation
    • Over/under voltage (27 / 59)
    • Engine cycle crank
    • Over/under frequency (81 o/u)
    • Remote CAN annunciator
    • Remote Serial annunciator
    • kW (per phase, average & percent)
    • Digital I/O module
    • Failure to start (overcrank)
    • Low oil pressure
    • Low coolant level
    • Run/auto/ stop/control
    • 6 programmable digital inputs
    • Accessory module data link
    • Features include:
    • Compatible with the following optional modules:
    • Serial annunciator module data link
    • kVA (per phase, average & percent)
    • Voltage adjust
    • RPM
    • Generator temperature monitoring module
    • kVAr (per phase, average & percent)
    • 2 Programmable relay outputs (Form C)
    • DC volts
    • Communications
    • Local annunciator
    • Power factor (per phase & average)
    • Speed adjust
    • Emergency stop
    • Reverse power (kW) (32)
    • coolant temperature
    • Digital indication for:
    • Reverse reactive power (kVAr) (32RV)
    • Customer data link (Modbus RTU)
    • kW-hr (total)
    • Amps (per phase & average)
    • High coolant temperature
    • Generator phase sequence
    • Oil pressure (psi, kPa or bar)
    • Operating hours
    • 2 Programmable digital outputs
    • Environmental sealed front face
  • Cooling System
    • Fan and belt guards
    • Radiator with guard (Sized for 50 degrees C)
    • Coolant drain line with valve, piped to edge of base
    • Coolant level shutdown
    • Caterpillar extended life coolant
  • Exhaust System
    • Stainless steel exhaust flex with ANSI style outlet flange, gasket, bolts and mating weld flange, shipped loose
  • Fuel System
    • Primary and Secondary fuel filters
    • Water seperator
    • Flexible fuel lines terminated on base
    • Fuel priming pump
  • Generator and Attachments
    • 3-phase sensing
    • Busbar termination
    • SR4B self excited
    • 2:1 Volts/Hz
    • Class F temperature rise
    • 12 Leads
    • Class H insulation
    • Reactive droop
    • VR6 voltage regulator
  • Governing System
    • Cat electronic governor
  • Lube System
    • Oil drain line with valve, piped to edge of base
    • Oil filter
    • Fumes disposal, piped to front of radiator
    • Lubricating oil
  • Mounting System
    • Base, formed steel with linear vibration isolators between base and engine-generator
  • Starting / Charging System
    • Fuel shutoff solenoid
    • 45 amp Charging alternator
    • Battery with rack, cables
    • 24 volt starting motor
  • Air Inlet System
    • Dual element air cleaners
    • Heavy duty air cleaners
    • Open element air cleaners
  • Circuit breakers
    • 1250, 1600 Amp, 3 pole, IEC 100% rated, 24 volt DC shunt trip
    • 1600 Amp, 3 pole, Non-UL, 100% rated, 24 volt DC shunt trip
  • Control Panel
    • Ground fault relay
    • Vandal proof panel door
    • First local annunicators
    • Common alarm/shutdown relay
    • Remote custom annunicator
    • GCCP Control panel
    • Generator running VFC
    • GCCP Control panel
    • Local discrete I/O package
    • Generator temperature monitoring package
  • Cooling System
    • Radiator duct flange
    • Jacket water heaters
  • European Certifications
    • Eurasian Conformity (EAC) mark
  • Exhaust System
    • Manifold and turbocharger guards
    • Through wall installation kit
    • Elbow kit
    • Mufflers
  • Generator and Attachments
    • Permanent magnet excitation (PMG)
    • Space heater
    • Digital voltage regulator
    • Oversize and premium generators
  • Lube System
    • Manual sump pump
  • Mounting System
    • Fuel tank base (1200 ltr)
  • Special Tests / Reports
    • PGS Test report @ 0.8 power factor
    • PGS Test report @ 1.0 power factor
  • Starting / Charging
    • Battery disconnect switch
    • Heavy duty starting system
    • Battery chargers
    • Oversize batteries
  • Governing System
    • Electronic load share