Piscataway Campus
732-885-5555
Bensalem Campus
877-726-7663

Diesel Generator Sets

3412C | 750kVA 50Hz Generator Set

  • Maximum Rating
    680 kVA
  • Minimum Rating
    680 kVA
  • Emissions
    Low Fuel Consumption
  • Voltage
    380 to 415 Volts
Generator Set Specifications
Maximum Rating
680 kVA
Minimum Rating
680 kVA
Emissions
Low Fuel Consumption
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Prime
Engine Specifications
Engine Model
3412C TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
5.4 in
Stroke
6 in
Displacement
1648.86 in³
Compression Ratio
13:01
Aspiration
Turbocharged, Air to Air Aftercooled
Fuel System
Pump and Lines
Governor Type
ADEM™ A5
Generator Set Dimensions
Length
162.4 in
Width
75 in
Width
78.3 in
Height
75 in
Dry Weight
12039 lb
Dry Weight
13030 lb
  • Air Inlet System
    • Air cleaner, single element canister type with service indicator
  • Control Panel
    • GCCP Control panel
    • Over/under voltage (27 / 59)
    • Environmental sealed front face
    • Generator phase sequence
    • Communications
    • Digital I/O module
    • Features include:
    • 2 Programmable relay outputs (Form C)
    • Compatible with the following optional modules:
    • Customer data link (Modbus RTU)
    • 4 programmable relay outputs (Form A)
    • Amps (per phase & average)
    • kVA (per phase, average & percent)
    • Text alarm/event descriptions
    • Low coolant level
    • Generator temperature monitoring module
    • Run/auto/ stop/control
    • Overspeed
    • Serial annunciator module data link
    • Emergency stop pushbutton
    • Frequency (Hz)
    • RPM
    • 6 programmable digital inputs
    • Oil pressure (psi, kPa or bar)
    • Engine cycle crank
    • Operating hours
    • Local annunciator
    • coolant temperature
    • kW-hr (total)
    • Programmable protective relaying functions:
    • kW (per phase, average & percent)
    • Low oil pressure
    • Reverse power (kW) (32)
    • Remote Serial annunciator
    • DC volts
    • Power factor (per phase & average)
    • Remote CAN annunciator
    • 24 Volt DC operation
    • Accessory module data link
    • Failure to start (overcrank)
    • Over/under frequency (81 o/u)
    • kVAr (per phase, average & percent)
    • Warning/shutdown with common LED indication of shutdowns for:
    • Low coolant temperature
    • 2 Programmable digital outputs
    • Reverse reactive power (kVAr) (32RV)
    • Emergency stop
    • Digital indication for:
    • High coolant temperature
    • Speed adjust
    • Voltage adjust
    • Volts (L-L & L-N)
    • Overcurrent (50 / 51)
  • Cooling System
    • Fan and belt guards
    • Coolant drain line with valve, piped to edge of base
    • Caterpillar extended life coolant
    • Coolant level shutdown
    • Radiator with guard (Sized for 50 degrees C)
  • Exhaust System
    • Stainless steel exhaust flex with ANSI style outlet flange, gasket, bolts and mating weld flange, shipped loose
  • Fuel System
    • Flexible fuel lines terminated on base
    • Fuel priming pump
    • Primary and Secondary fuel filters
    • Water seperator
  • Generator and Attachments
    • 3-phase sensing
    • SR4B self excited
    • Class H insulation
    • 2:1 Volts/Hz
    • Reactive droop
    • VR6 voltage regulator
    • Busbar termination
    • Class F temperature rise
    • 12 Leads
  • Governing System
    • Cat electronic governor
  • Lube System
    • Oil drain line with valve, piped to edge of base
    • Lubricating oil
    • Oil filter
    • Fumes disposal, piped to front of radiator
  • Mounting System
    • Base, formed steel with linear vibration isolators between base and engine-generator
  • Starting / Charging System
    • Battery with rack, cables
    • 45 amp Charging alternator
    • 24 volt starting motor
    • Fuel shutoff solenoid
  • Air Inlet System
    • Open element air cleaners
    • Heavy duty air cleaners
    • Dual element air cleaners
  • Circuit breakers
    • 1600 Amp, 3 pole, Non-UL, 100% rated, 24 volt DC shunt trip
    • 1250, 1600 Amp, 3 pole, IEC 100% rated, 24 volt DC shunt trip
  • Control Panel
    • First local annunicators
    • Local discrete I/O package
    • Generator temperature monitoring package
    • Ground fault relay
    • Remote custom annunicator
    • GCCP Control panel
    • Generator running VFC
    • GCCP Control panel
    • Vandal proof panel door
    • Common alarm/shutdown relay
  • Cooling System
    • Jacket water heaters
    • Radiator duct flange
  • European Certifications
    • Eurasian Conformity (EAC) mark
  • Exhaust System
    • Elbow kit
    • Manifold and turbocharger guards
    • Through wall installation kit
    • Mufflers
  • Generator and Attachments
    • Digital voltage regulator
    • Oversize and premium generators
    • Space heater
    • Permanent magnet excitation (PMG)
  • Lube System
    • Manual sump pump
  • Mounting System
    • Fuel tank base (1200 ltr)
  • Special Tests / Reports
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
  • Starting / Charging
    • Heavy duty starting system
    • Battery chargers
    • Battery disconnect switch
    • Oversize batteries
  • Governing System
    • Electronic load share