3412C | 800 kVA 50Hz Generator Set

  • Maximum Rating
    680 kVA
  • Minimum Rating
    680 kVA
  • Emissions
    Low Fuel Consumption
  • Voltage
    380 to 415 Volts
Generator Set Specifications
Maximum Rating
680 kVA
Minimum Rating
680 kVA
Emissions
Low Fuel Consumption
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Prime
Engine Specifications
Engine Model
3412C TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
5.4 in
Stroke
6 in
Displacement
1648.86 in³
Compression Ratio
13:01
Aspiration
Turbocharged, Air to Air Aftercooled
Fuel System
Pump and Lines
Governor Type
ADEM™ A5
Generator Set Dimensions
Length
162.4 in
Width
75 in
Width
78.3 in
Height
75 in
Dry Weight
12039 lb
Dry Weight
13030 lb
  • Air Inlet System
    • Air cleaner, single element canister type with service indicator
  • Control Panel
    • GCCP Control panel
    • DC volts
    • Environmental sealed front face
    • kVA (per phase, average & percent)
    • Voltage adjust
    • Compatible with the following optional modules:
    • Low coolant level
    • RPM
    • Engine cycle crank
    • Over/under frequency (81 o/u)
    • Programmable protective relaying functions:
    • kVAr (per phase, average & percent)
    • coolant temperature
    • Local annunciator
    • Reverse reactive power (kVAr) (32RV)
    • 2 Programmable digital outputs
    • Emergency stop
    • Amps (per phase & average)
    • Volts (L-L & L-N)
    • Failure to start (overcrank)
    • Speed adjust
    • 24 Volt DC operation
    • Remote Serial annunciator
    • kW (per phase, average & percent)
    • Low coolant temperature
    • High coolant temperature
    • Over/under voltage (27 / 59)
    • Reverse power (kW) (32)
    • Run/auto/ stop/control
    • Operating hours
    • Customer data link (Modbus RTU)
    • Power factor (per phase & average)
    • Generator temperature monitoring module
    • 6 programmable digital inputs
    • Overspeed
    • Text alarm/event descriptions
    • 4 programmable relay outputs (Form A)
    • kW-hr (total)
    • Features include:
    • Remote CAN annunciator
    • Digital I/O module
    • Generator phase sequence
    • Low oil pressure
    • Warning/shutdown with common LED indication of shutdowns for:
    • Accessory module data link
    • Emergency stop pushbutton
    • Serial annunciator module data link
    • Frequency (Hz)
    • 2 Programmable relay outputs (Form C)
    • Oil pressure (psi, kPa or bar)
    • Digital indication for:
    • Communications
    • Overcurrent (50 / 51)
  • Cooling System
    • Caterpillar extended life coolant
    • Coolant level shutdown
    • Radiator with guard (Sized for 50 degrees C)
    • Fan and belt guards
    • Coolant drain line with valve, piped to edge of base
  • Exhaust System
    • Stainless steel exhaust flex with ANSI style outlet flange, gasket, bolts and mating weld flange, shipped loose
  • Fuel System
    • Water seperator
    • Flexible fuel lines terminated on base
    • Primary and Secondary fuel filters
    • Fuel priming pump
  • Generator and Attachments
    • Class H insulation
    • 2:1 Volts/Hz
    • 3-phase sensing
    • Class F temperature rise
    • 12 Leads
    • VR6 voltage regulator
    • Busbar termination
    • Reactive droop
    • SR4B self excited
  • Governing System
    • Cat electronic governor
  • Lube System
    • Lubricating oil
    • Oil drain line with valve, piped to edge of base
    • Fumes disposal, piped to front of radiator
    • Oil filter
  • Mounting System
    • Base, formed steel with linear vibration isolators between base and engine-generator
  • Starting / Charging System
    • 45 amp Charging alternator
    • Fuel shutoff solenoid
    • Battery with rack, cables
    • 24 volt starting motor
  • Air Inlet System
    • Heavy duty air cleaners
    • Open element air cleaners
    • Dual element air cleaners
  • Circuit breakers
    • 1600 Amp, 3 pole, Non-UL, 100% rated, 24 volt DC shunt trip
    • 1250, 1600 Amp, 3 pole, IEC 100% rated, 24 volt DC shunt trip
  • Control Panel
    • GCCP Control panel
    • Vandal proof panel door
    • Remote custom annunicator
    • Ground fault relay
    • Common alarm/shutdown relay
    • Generator running VFC
    • GCCP Control panel
    • Local discrete I/O package
    • First local annunicators
    • Generator temperature monitoring package
  • Cooling System
    • Jacket water heaters
    • Radiator duct flange
  • European Certifications
    • Eurasian Conformity (EAC) mark
  • Exhaust System
    • Through wall installation kit
    • Manifold and turbocharger guards
    • Elbow kit
    • Mufflers
  • Generator and Attachments
    • Digital voltage regulator
    • Oversize and premium generators
    • Permanent magnet excitation (PMG)
    • Space heater
  • Lube System
    • Manual sump pump
  • Mounting System
    • Fuel tank base (1200 ltr)
  • Special Tests / Reports
    • PGS Test report @ 0.8 power factor
    • PGS Test report @ 1.0 power factor
  • Starting / Charging
    • Battery disconnect switch
    • Oversize batteries
    • Battery chargers
    • Heavy duty starting system
  • Governing System
    • Electronic load share