Diesel Generator Sets
C13 Generator Set
-
Maximum Rating400 ekW
-
Minimum Rating320 ekW
-
EmissionsEPA Stationary Emerg Use
-
Voltage208 to 600 Volts
Generator Set Specifications
- Maximum Rating
- 400 ekW
- Minimum Rating
- 320 ekW
- Emissions
- EPA Stationary Emerg Use
- Voltage
- 208 to 600 Volts
- Frequency
- 60 Hz
- Speed
- 1800 rpm
- Duty Cycle
- Standby, Prime
Engine Specifications
- Engine Model
- C13 ACERT In-line 6, 4-cycle diesel
- Bore
- 5.12 in
- Stroke
- 6.2 in
- Displacement
- 763 in³
- Compression Ratio
- 16.3:1
- Aspiration
- Turbocharged Air to Air Aftercooled
- Fuel System
- MEUI
- Governor Type
- Adem™A4
Generator Set Dimensions
- Length
- 186.7 in
- Width
- 79.3 in
- Height
- 84 in
-
Air Inlet System
- Turbocharger
- Aftercooler core
- Air cleaner; light duty with disposable paper filter
-
Starting / Charging
- Charging alternator
- 24 Volt electric starting motor
-
Control Panel
- GCCP 1.3
-
Control System Controller
- GCCP 1.3
-
Cooling System
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
- Coolant drain line with valve
- Radiator and cooling fan with guard
-
Certification
- EPA stationary emergency use
-
Exhaust System
- Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
-
Base / Fuel Tank
- Audio and visual fuel alarm
-
Fuel System
- Standard open set fuel tank/base supplied
- Base, formed steel with single wall integral 8-hour fuel tank
-
Protection
- Safety shutoff - Overspeed
- Safety shutoff - Low oil pressure
- Safety shutoff - High water temperature
-
Generator and Attachments
- Segregated low voltage (AC/DC) wiring panel
- Power center, IP22
- A Frame generator - IP21 Protection
- Integrated voltage regulator (IVR)
- Optional LC Frame generator - IP23 Protection
- Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
-
Governing System
- Cat electronic governor (ADEM A4)
-
Lube System
- Oil cooler
- Oil drain valves
- Lubricating oil
-
Mounting System
- Includes lifting provisions and termination points for coolant and lube oil drain lines
- Captive linear vibration isolators between base and engine-generator
-
Starting / Charging System
- 24V battery with rack and cables
-
General
- Engine and alternator pre-paint, Caterpillar yellow
-
European Certificates
- Global Certification for CIS
- EU Certificate of Conformance (CE)
-
Air Inlet System
- Single element air cleaner
- Dual element air cleaner
-
Circuit breakers
- Padlockable circuit breaker device
- 3 Pole (IEC-100% rated) Circuit breaker
- Shunt trip for IEC circuit breaker
- 4 Pole (IEC-100% rated) Circuit breaker - Motorised
- Circuit breaker (IEC) Auxiliary contacts
- 4 Pole (IEC-100% rated) Circuit breaker
- Power terminal strip
- 3 Pole (IEC-100% rated) Circuit breakers - Motorised
-
Control Panels
- Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
- GCCP 1.4
- Volt free contacts
- Local alarm modules: Local annunciator
- Remote annunciator module
-
Cooling System
- Radiator duct flange
- Stone guards
- Low coolant temperature alarm
-
Enclosures
- Sound attenuated enclosures
- High ambient sound attenuated enclosures
-
Exhaust System
- Flexible 8 inch exhaust fittings
- Mufflers - End in/end out
- 10, 25 and 35 dBA attenuation
- 6 and 8 inch elbow kit
- 6 and 8 inch flange GP
-
Fuel System
- Fuel transfer system controls
- Manual fuel transfer pump
- Integral dual wall fuel tank base
-
Generator and Attachments
- LC frame generator
- LC CIP generator
- Space heaters
- Ingress protection
- A Frame oversize generator
- Permanent magnet excitation (PMG) generator
- A Frame CIP generator
-
Lube System
- Manual sump pump
-
Mounting System
- Narrow skid base
-
starting / Charging System
- Battery disconnect switch
- Jacket water heater
- 5 Amp single Battery charger