Piscataway Campus
732-885-5555
Bensalem Campus
877-726-7663

Diesel Generator Sets

D80 GC Generator Set

  • Maximum Rating
    80 ekW
  • Minimum Rating
    80 ekW
  • Emissions
    U.S. EPA Cert., Tier 3
  • Voltage
    208 to 600 Volts
Generator Set Specifications
Maximum Rating
80 ekW
Minimum Rating
80 ekW
Emissions
U.S. EPA Cert., Tier 3
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby
Engine Specifications
Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.1 in
Stroke
5 in
Displacement
269 in³
Compression Ratio
16.7:1
Aspiration
Turbocharged
Fuel System
Common Rail
Governor Type
Mechanical, ADEM™A4
Generator Set Dimensions
Length
82.6 in
Width
43.3 in
Height
52.9 in
Dry Weight
950 lb
  • Air Inlet System
    • Air cleaner; light duty with disposable element
    • Air cleaner
  • Cooling System
    • Radiator and cooling fan with guards
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
    • Coolant drain line with valve
  • Control Panel
    • GCCP 1.2 Control panel
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
  • Generator
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
    • Voltage regulator (single phase sensing)
    • IP23 Protection
    • Segregated low voltage (AC/DC) wiring panel
    • 12 Leads
    • Tower panel, IP22, bottom cable entry
  • Governing System
    • Mechanical and electrical governing system - model dependent
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Mounting System
    • Includes lifting provision and drag points
    • Termination points for coolant and lube oil drain lines
    • Captive linear vibration isolators between base and engine-generator
  • Starting/Charging System
    • Batteries
    • 24V battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • Alternator System
    • 3 Phase sensing
    • Anti-condensation heater
    • R Frame auxilliary winding
    • Permanent magnet excitation (PMG)
  • Circuit breakers
    • Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
  • Cooling System
    • Low coolant level shutdown
    • Coolant heater
    • Low coolant temperature alarm
  • Control Panel Options
    • Earth fault (2 wire only)
    • Overload shutdown via breaker
    • Earth leakage (2 wire only)
    • Volt free contacts
    • Panel mounted audible alarm
    • Battery charger
    • GCCP 1.2 Control panel
    • Control panel heater
    • Voltage adjust potentiometer
    • Emergency stop with key
    • Speed adjust potentiometer
  • Enclosures
    • Sound attenuated Level 2 enclosure
  • Fuel System
    • High fuel level alarm
    • Open set narrow tankbase
    • Low fuel level alarm
    • Bunded fuel tank
    • Low fuel level shutdown
    • Compact skidbase for open set
    • Skidbase for CALG enclosure sets
  • Global Certifications
    • Certification for CIS
  • Mounting Options
    • Battery removal
    • Industrial silencer
    • Electronic governor
    • External single point lift - enclosure
    • Silencer installation kit
  • Special Packing/Inspectons for Shipment
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
  • General - Accessories / Miscellaneous
    • Stone guards/rad trans flange
    • Packing case - canopied set
    • Packing case - compact set