Diesel Generator Sets
DE400 GC Generator Set
-
Maximum Rating400 kVA
-
Minimum Rating400 kVA
-
EmissionsNon-Certified Emissions
-
Voltage380 to 415 Volts
Generator Set Specifications
- Maximum Rating
- 400 kVA
- Minimum Rating
- 400 kVA
- Emissions
- Non-Certified Emissions
- Voltage
- 380 to 415 Volts
- Frequency
- 50 Hz
- Speed
- 1500 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- C9.3B, I-6, 4-cycle diesel
- Bore
- 4.53 in
- Stroke
- 5.87 in
- Displacement
- 567.5 in³
- Compression Ratio
- 16.5:1
- Aspiration
- Turbocharged Air-to-Air Aftercooled
- Fuel System
- Common Rail
- Governor Type
- ADEM™A6
Generator Set Dimensions
- Length
- 104.8 in
- Width
- 44 in
- Height
- 69.5 in
- Dry Weight
- 5070.6 lb
-
Engine
- C9.3B, Inline 6 cylinder, 4 stroke diesel
-
Air, Cooling & Exhaust
- Standard air filter
-
Genset Control
- GCCP 1.1
-
Governor
- Adem A4
-
Alternator
- A Frame standard alternator
-
Fuel Storage
- Single wall 8 hour fuel tank
-
General
- Engine and alternator pre-paint, Caterpillar yellow
-
Air, Cooling & Exhaust
- 6" Elbow kit
- Dual element air filter
- 5-6" Exhaust adapter
- Canopy silencer
- 5" Elbow kit
- 6" Elbow kit
- 6" Muffler - 25 dBA attenuation
- 5" Muffler - 10 dBA Attenuation
- Single stage air filter
- No muffler
-
Alternator Requirements
- IP Standard @ 21 FUW A-Frame
- Space heater
-
Auxiliary Supply Voltage
- 240V
-
Certification
- Australia, CIS, Gulf Certification
- Certificate of Conformance 13
-
Circuit breaker
- 3 Pole Circuit breaker 800A
- Circuit breaker padlock
- 4 Pole Circuit breaker 630A
- 4 Pole Circuit breaker 1250A
- 3 Pole Circuit breaker 630A
- 4 Pole Circuit breaker 800A
- Overload via alarm switch on breaker
- Neutral earth link
- 3 Pole Circuit breaker 1250A
- Auxiliary contacts
- Shunt Trip
-
Enclosure
- Cat GC enclosure
-
Fuel Storage
- Low fuel level shutdown
- Fuel level alarms
- Low fuel level alarm
- Single wall tank with containment 01
- High fuel level alarm
- Dual wall 8 hour fuel tank
-
Genset Control
- PLG Cellular 4G E
- Oil temperature displays
- Coolant heater
- Battery charger
- Standby Pack (Smart Jacket water heater, Battery charger)
- PLG Cellular 4G U
- Voltage adjust potentiometer
- Low coolant temperature alarm
- Speed adjust potentiometer
- PLG Ethernet
- Battery