Electric Power
XQC1200
-
Rating1150kW (1438 kVA) Continuous
-
Frequency50/60 Hz
-
Voltage230 - 480 V
-
IPP Overload 50Hz1205 ekW (1506 kVA)
Generator Set
- Rating
- 1150kW (1438 kVA) Continuous
- Frequency
- 50/60 Hz
- Voltage
- 230 - 480 V
- IPP Overload 50Hz
- 1205 ekW (1506 kVA)
- IPP Overload 60Hz
- 1330kW; (1662KVA)
- IPP Rated 60Hz
- 1260 ekW (1575 kVA)
Engine
- Engine
- Cat 3512C
- Fuel
- Diesel
Dimensions
- Height
- 114 in
- Length
- 240 in
- Weight
- 47440 lb
- Width
- 97.5 in
-
Cat 3512C heavy duty diesel engine
- Heavy duty, dual element, PowerCore air cleaners with service indicators
- Secondary fuel filters
- Full flow oil filters with water-cooled oil cooler. Requires API CI-4 or higher lube oil
- Lubricating oil system includes make-up system (113-L tank), oil drain lines routed to the engine rail, and quick evacuation system for faster, cleaner oil changes
- Jacket water heater (9 kW, 3-phase 480VAC) with electric pump
- Fuel cooler and electric priming pump
- Electronic differential pressure monitoring of all filters
- Electronic ADEM™ A4 engine controls
- 24V electric starting motor
-
SR5 Generator
- Double-bearing, SR-5 generator with anti-condensation space heaters (1.2 kW, 480VAC)
- Brushless, random-wound, permanent magnet excited, thouree-phase, 4-lead design
- Class H insulation operating at Class F temperature for extended life
- Cat Integrated Voltage Regulator (Cat IVR)
- Stator winding and bearing temperature sensors and RTD module
- Metallic mesh generator air inlet filters (washable) with differential pressure monitoring
- Coastal Insulation Protection
-
20' ISO high-cube container, 9-High stackable, CSC certified
- Hinged, radiator air intake louvers
- Sound-attenuated engine room air intake louvers with foldable awnings that double as shipping covers
- Two (2) lockable personnel doors with panic releases
- Interior walls and ceilings insulated with 50 mm of acoustic paneling
- Side bus bar access door with external access load cable connections
- Shore power via distribution block connections for jacket water heater, battery charger, and generator Anti-condensation Heaters
- Four (4) DC lights with 60-min timer
- Single-wall, 378-L (100gal) fuel tank; certified to BS799-5
- Solenoid fuel-fill control valve for automated tank filling
- Triple, primary fuel filters with integral water separators and service valves for on-the-fly changes
- Sound attenuated to 83 dBA (50 Hz) / 85 dBA (60 Hz) at 7m (23 ft)
- Two (2) 1400-CCA, Group 4D, maintenance-free batteries and 50-Amp battery charger
- Insulated exhaust silencer with 1.8m (6ft) stainless steel exhaust stack for increased site power density
- Engine vibration isolators
- Easy drain access to standard fluids
- Standard Cat decals and painted Cat Power Module White
-
Cooling
- Cooling package provides 40°C (104F) ambient capability at 50 Hz, or 42°C (108F) capability at 60 Hz at the IPP Rating at 750m (2,460 ft) above sea level
- Vertical, non-stacked radiator cores with dimpled fins and vertical air discharge
- Variable frequency fan drive with smart fan control
- Cat Extended Life Coolant (ELC)
-
Generator Controls and Protection
- EMCP 4.3 generator set mounted controller
- Automatic start/stop with cool down timer
- Generator Protection features: 25, 32, 40, 50/51, 27/59, 81 O/U
- AGC-4 provides voltage and frequency adjust, base load / PF / load sharing / synchouronizer, auto start / stop control & generator CB control, SCADA Interface (Ethernet), fuel level Indications & alarms, and fuel tank fuel transfer control
- Reverse compatibility for interface to legacy power modules
- 100 kAIC, 4000A-Frame generator circuit breaker with LSIG trip unit
- Multi-mode operation: Island (kW/kVAR sharing), Base load power, Power management with multiple units
- Manual and automatic paralleling capability
- Metering display: voltage, current, frequency, power factor, kW, WHM, kVAR, and synchouroscope
-
Quality
- Factory testing of complete power module
- CE Certified, NEMA, ISO and IEEE standards
- O&M manuals