Piscataway Campus
732-885-5555
Bensalem Campus
877-726-7663

Gas Compression Electric Motors

CN5086 Electric Motor

  • Voltage
    4000V ± 10%/60 Hz
  • Type of EX
    Class 1 Division 2, Group A,B,C,D T3 (NEC or CEC)
  • Number of Poles
    8
  • Electric Motor Type
    Squirrel Cage Induction Motor
Electric Motor Specifications
Voltage
4000V ± 10%/60 Hz
Type of EX
Class 1 Division 2, Group A,B,C,D T3 (NEC or CEC)
Number of Poles
8
Electric Motor Type
Squirrel Cage Induction Motor
Full Load Speed
894 r/min
Mounting Designation
F1 or F2
Number of Poles
8
Enclosure Type
WP-II
Insulation
Class F
Service Factor
1.15 SF
Standards
NEMA MG1
Max Ambient Temperature
104 °F
Max Altitude Before Derate
3000 ft
Duty
Continuous
Temperature Rise
Class B at rated load
Connection of Stator Winding
Star
Full Load Current
658 Amps
Locked Rotor Amps
520% Code E
Locked Rotor Torque
60%
Breakdown Torque
190%
No Load Current
200 Amps
Rated Torque
29366 lb-ft
Shaft
8.5 in
Connection of Stator Winding
Star
Duty
Continuous
Enclosure Type
WP-II
Full Load Current
658 Amps
Insulation
Class F
Locked Rotor Amps
520% Code E
Locked Rotor Torque
60%
Maximum Altitude
3000 ft
Maximum Ambient Temperature
104 °F
No Load Current
200 Amps
Rated Torque
29366 lb/ft
Shaft
8.5 in
Standards
NEMA MG1
Temperature Rise
Class B at rated load
  • Bearings
    • Self-lubricated sleeve bearings
    • Insulated non-drive end bearings to reduce bearing currents
    • Bearing RTDs for temperature monitoring
  • Rotors
    • Designed for minimal vibration
    • Dynamic balancing at full operational speed
    • Fabricated copper squirrel cages
    • Oversized, forged, keyless shaft
    • AISI 4140/DIN42CrMo4 shaft
  • Stators
    • Radial air ducts ensure uniform and efficient cooling
    • Vacuum pressure impregnated with specially formulated epoxy resin
    • 2X RTDS per Phase
    • Space heater
    • Welded and machined stator core retains its rigidity throughout motor life to ensure a sealed and homogeneous insulation system that results in high dielectric strength, excellent heat transfer and the elimination of hazardous internal partial discharges