Piscataway Campus
732-885-5555
Bensalem Campus
877-726-7663

Marine Generator Sets

C18 Marine Generator Set

  • Minimum Rating
    260 ekW (325 kVA)
  • Power Range
    260 - 565 ekW
  • Maximum Rating
    565 ekW (706 kVA)
  • Frequency
    50 / 60
Generator Set Specifications
Minimum Rating
260 ekW (325 kVA)
Maximum Rating
565 ekW (706 kVA)
Frequency
50 / 60
Frequency
50 hz
Speed
50 Hz - 1500 rpm, 60 Hz - 1800 rpm
Speed
50 Hz - 1500 rpm, 60 Hz - 1800 rpm
Minimum Rating
260 ekW (325 kVA)
Maximum Rating
565 ekW (706 kVA)
Power Rating
Power Range
260 - 565 ekW
Engine Specifications
Configuration
In-line 6, 4-Stroke-Cycle Diesel
Configuration
In-line 6, 4-Stroke-Cycle Diesel
Aspiration
Turbocharged - aftercooled
Aspiration
Turbocharged - aftercooled
Bore
5.7 in
Bore
5.7 in
Stroke
7.2 in
Stroke
7.2 in
Fuel System
MEUI
Generator Set Configurations
Emissions
EPA Tier 3, IMO II, EU IWW
Generator Set Dimensions (Keel and Hex Cooled)
Length
119.6 in
Height
64.9 in
Generator Set Dimensions (Radiator Cooled)
Length
55.6 in
Height
94.8 in
Generator Set Dimensions - Keel and Hex Cooled
Height
64.9 in
Length
119.6 in
Width
55.6 in
Weight
9747 lb
Generator Set Dimensions - Radiator Cooled
Height
94.8 in
Length
55.6 in
Width
66.9 in
Weight
13396 lb
Generator Specifications
Excitation
SRMP
Insulation
Class H
IP Rating
IP23 (standard), IP 44 (optional)
Voltage Regulator
CDVR (Digital Voltage)
  • Air inlet system
    • Separate circuit after-cooled (SCAC)
    • Heavy-duty inlet air filter
  • Cooling system
    • SCAC pump, gear driven, for HEX cooled engines only
    • Jacket water pump, gear driven
    • SCAC and JW shunt tanks for maintaining proper pump inlet pressures
  • Exhaust system
    • Water-cooled exhaust manifold & turbocharger
    • Round flanged exhaust outlet
  • Fuel system
    • Hybrid fuel lines
    • MEUI fuel system
    • Fuel filter, front service
    • Fuel transfer and priming pumps
  • Lube system
    • Center sump oil pan, deep
    • Front and top service oil filler locations
    • Front service dipstick
  • Mounting system
    • Vibration Isolators
    • Formed C-channel rails
  • Control system
    • Electronic fuel/air ratio control
    • SRMP permanent magnet 12-lead generator
    • Digital voltage regulator
    • Class H insulation, Class F temperature rise, IP23 protection
  • Exhaust system
    • Dry Elbows
    • Water-Cooled Elbows
    • Flexible Fitting
    • Flange
    • Muffler
    • Muffler, Spark Arresting
    • Fumes disposal (closed system)
  • Air inlet system
    • Air Inlet Adapter
  • Charging system
    • Battery Chargers 10 amp
    • Battery sets: 24V 950-1300 CCA
    • Charging alternator 24V 105 amp
  • Control system
    • Caterpillar alarm and protection
    • EMCP 4.2 control panel
    • MGCP III B control panel
  • Fuel system
    • Duplex fuel filter – front service
    • Fuel cooler
    • Primary fuel/water separator
  • Instrumentation
    • Generator service side - LH, RH
    • Generator terminal box extension
    • Load sharing module (option for type approved module)
  • Lube system
    • Spare pump kits
    • Duplex oil filter – front service
    • Manual sump pump
  • Mounting system
    • Vibration Isolators
  • Protection system
    • Generator protection - IP44
  • Starting system
    • Starting motors - electric and/or air
    • Jacket water heaters