Marine Generator Sets
C18 Marine Generator Set
-
Minimum Rating260 ekW (325 kVA)
-
Power Range260 - 565 ekW
-
Maximum Rating565 ekW (706 kVA)
-
Frequency50 / 60
Generator Set Specifications
- Minimum Rating
- 260 ekW (325 kVA)
- Maximum Rating
- 565 ekW (706 kVA)
- Frequency
- 50 / 60
- Frequency
- 50 hz
- Speed
- 50 Hz - 1500 rpm, 60 Hz - 1800 rpm
- Speed
- 50 Hz - 1500 rpm, 60 Hz - 1800 rpm
- Minimum Rating
- 260 ekW (325 kVA)
- Maximum Rating
- 565 ekW (706 kVA)
Power Rating
- Power Range
- 260 - 565 ekW
Engine Specifications
- Configuration
- In-line 6, 4-Stroke-Cycle Diesel
- Configuration
- In-line 6, 4-Stroke-Cycle Diesel
- Aspiration
- Turbocharged - aftercooled
- Aspiration
- Turbocharged - aftercooled
- Bore
- 5.7 in
- Bore
- 5.7 in
- Stroke
- 7.2 in
- Stroke
- 7.2 in
- Fuel System
- MEUI
Generator Set Configurations
- Emissions
- EPA Tier 3, IMO II, EU IWW
Generator Set Dimensions (Keel and Hex Cooled)
- Length
- 119.6 in
- Height
- 64.9 in
Generator Set Dimensions (Radiator Cooled)
- Length
- 55.6 in
- Height
- 94.8 in
Generator Set Dimensions - Keel and Hex Cooled
- Height
- 64.9 in
- Length
- 119.6 in
- Width
- 55.6 in
- Weight
- 9747 lb
Generator Set Dimensions - Radiator Cooled
- Height
- 94.8 in
- Length
- 55.6 in
- Width
- 66.9 in
- Weight
- 13396 lb
Generator Specifications
- Excitation
- SRMP
- Insulation
- Class H
- IP Rating
- IP23 (standard), IP 44 (optional)
- Voltage Regulator
- CDVR (Digital Voltage)
-
Air inlet system
- Separate circuit after-cooled (SCAC)
- Heavy-duty inlet air filter
-
Cooling system
- SCAC pump, gear driven, for HEX cooled engines only
- Jacket water pump, gear driven
- SCAC and JW shunt tanks for maintaining proper pump inlet pressures
-
Exhaust system
- Water-cooled exhaust manifold & turbocharger
- Round flanged exhaust outlet
-
Fuel system
- Hybrid fuel lines
- MEUI™ fuel system
- Fuel filter, front service
- Fuel transfer and priming pumps
-
Lube system
- Center sump oil pan, deep
- Front and top service oil filler locations
- Front service dipstick
-
Mounting system
- Vibration Isolators
- Formed C-channel rails
-
Control system
- Electronic fuel/air ratio control
- SRMP permanent magnet 12-lead generator
- Digital voltage regulator
- Class H insulation, Class F temperature rise, IP23 protection
-
Exhaust system
- Dry Elbows
- Water-Cooled Elbows
- Flexible Fitting
- Flange
- Muffler
- Muffler, Spark Arresting
- Fumes disposal (closed system)
-
Air inlet system
- Air Inlet Adapter
-
Charging system
- Battery Chargers 10 amp
- Battery sets: 24V 950-1300 CCA
- Charging alternator 24V 105 amp
-
Control system
- Caterpillar alarm and protection
- EMCP 4.2 control panel
- MGCP III B control panel
-
Fuel system
- Duplex fuel filter – front service
- Fuel cooler
- Primary fuel/water separator
-
Instrumentation
- Generator service side - LH, RH
- Generator terminal box extension
- Load sharing module (option for type approved module)
-
Lube system
- Spare pump kits
- Duplex oil filter – front service
- Manual sump pump
-
Mounting system
- Vibration Isolators
-
Protection system
- Generator protection - IP44
-
Starting system
- Starting motors - electric and/or air
- Jacket water heaters