Piscataway Campus
732-885-5555
Bensalem Campus
877-726-7663

Marine Generator Sets

C18 Marine Generator Set

  • Minimum Rating
    260 ekW (325 kVA)
  • Power Range
    260 - 565 ekW
  • Maximum Rating
    565 ekW (706 kVA)
  • Frequency
    50 / 60
Generator Set Specifications
Minimum Rating
260 ekW (325 kVA)
Maximum Rating
565 ekW (706 kVA)
Frequency
50 / 60
Frequency
50 hz
Speed
50 Hz - 1500 rpm, 60 Hz - 1800 rpm
Speed
50 Hz - 1500 rpm, 60 Hz - 1800 rpm
Minimum Rating
260 ekW (325 kVA)
Maximum Rating
565 ekW (706 kVA)
Power Rating
Power Range
260 - 565 ekW
Engine Specifications
Configuration
In-line 6, 4-Stroke-Cycle Diesel
Configuration
In-line 6, 4-Stroke-Cycle Diesel
Aspiration
Turbocharged - aftercooled
Aspiration
Turbocharged - Aftercooled
Bore
5.7 in
Bore
5.7 in
Stroke
7.2 in
Stroke
7.2 in
Fuel System
MEUI
Oil Change Interval
250 / 500 hours
Governor
Electronic
Refill Capacity
68
Cooling
Heat Exchanger, Keel, Radiator Cooled
Rotation from Flywheel End
SAE No. (136 teeth)
Generator Set Configurations
Emissions
EPA Tier 3, IMO II, EU IWW, EU Stage V, China II
Generator Set Dimensions (Keel and Hex Cooled)
Length
119.6 in
Height
64.9 in
Generator Set Dimensions (Radiator Cooled)
Length
55.6 in
Height
94.8 in
Generator Set Dimensions - Keel and Hex Cooled
Height
64.9 in
Length
119.6 in
Width
55.6 in
Weight
9747 lb
Generator Set Dimensions - Radiator Cooled
Height
94.8 in
Length
55.6 in
Width
66.9 in
Weight
13396 lb
Generator Specifications
Excitation
SRMP
Insulation
Class H
IP Rating
IP23 (standard), IP 44 (optional)
Voltage Regulator
CDVR (Digital Voltage)
  • Air inlet system
    • Separate circuit after-cooled (SCAC)
    • Open Crankcase Ventilation (OCV) system
  • Turbocharger, jacket water cooled
  • Turbocharger inlet, 152 mm (6 in) OD straight connection
  • Cooling system
    • SCAC pump, gear driven, for HEX cooled engines only
    • Jacket water pump, gear driven
    • SCAC and JW shunt tanks for maintaining proper pump inlet pressures
  • Exhaust system
    • Water-cooled exhaust manifold & turbocharger
    • Round flanged exhaust outlet
  • Fuel system
    • Hybrid fuel line design
    • Fuel transfer pump, gear driven
    • Front service simplex fuel system
    • Manual fuel priming pump
  • Lube system
    • Center sump oil pan: Deep 500 hour oil change interval
    • Front and top service oil filler locations
    • Front service dipstick
  • Oil pump, gear driven
  • Mounting system
    • Vibration Isolators
    • Formed C-channel rails
  • Control system
    • Common Interface to all Genset Control Panels
    • Programmable Low Idle
    • Electronic Diagnostics and Fault Logging
    • Electronic Fuel/Air Ratio Control
  • Programmable ECM Shutdowns for: High Jacket Water Coolant Temp Low Engine Oil Pressure Engine Overspeed
  • Exhaust system
    • Dry Elbows
    • Water-Cooled Elbows
    • Flexible Fitting
    • Flange
    • Muffler
    • Muffler, Spark Arresting
  • Air inlet system
    • Air Inlet Adapter
  • Charging system
    • Battery Chargers 10 amp
    • Charging alternator 24V 105 amp
  • Control system
    • Caterpillar alarm and protection
    • EMCP 4.2 control panel
    • MGCP III B control panel
  • Fuel system
    • Duplex fuel filter – front service
    • Fuel cooler
    • Primary fuel/water separator
  • Instrumentation
    • Generator service side - LH, RH
    • Generator terminal box extension
    • Load sharing module (option for type approved module)
  • Lube system
    • Duplex oil filter
    • Sump pump
  • Protection system
    • Generator protection - IP44
  • Starting system
    • Starting motors - electric and/or air
    • Jacket water heaters